ecatalog2015.indd - page 66

Item # Vendor # Item Description
Lgth " DPM Qty
41776 *2C7562
BURETROL Solution Set with 150 mL Valveless Burette, 3 INTERLINK injection sites, Male Luer lock
adapter. For use with COLLEAGUE and FLO-GARD 6201 and 6301 Series Pumps. Contains DEHP, Fluid
path is sterile, nonpyrogenic.
115 60 12
42361 *2C8862
BURETROL Solution Set with 150 mL CLEARLINK Burette (Valveless), 3 CLEARLINK Y-Sites (Luer
Activated Valves), Male Luer Lock Adapter with Retractable Collar. For use with the COLLEAGUE and
FLO-GARD 6201 and 6301 Series Pumps. Approximate Length 115" (2.9 m), Approximately 60 drops/mL.
Contains DEHP. Fluid path is sterile, nonpyrogenic.
115 60 48
36429 *2C8671
Extension Set with 0.22 Micron High Pressure Extended Life Filter** and a CLEARLINK Luer Activated
Valve, Male Luer Lock Adapter with Retractable Collar, Approximate Volume 5.1 mL. ** Filter has passed
bacterial and pyrogen retention testing for 96 hours. Contains DEHP. Sterile package
16
48
22999 2N1191
Microbore Y-Type Catheter Extension Set w/male Luer lock adapter. Sterile package. Non-DEHP.
4.8
50
23753 2N1194
Microbore I.V. Catheter Extension Set with male Luer lock adapter. Sterile package. Non-DEHP.
7
50
25700 *2N8374
I.V. Catheter Extension Set with a CLEARLINK Luer Activated Valve, Male Luer Lock Adapter, non-DEHP.
Sterile package.
8.2
50
24713 2N8399
CLEARLINK Luer Activated Valve w/male Luer lock adapter. Sterile Package. Non-DEHP, Non-PVC.
200
11917 *2N3399
INTERLINK Injection Site with male Luer lock adapter. Sterile package. non-DEHP, non-PVC.
200
25895 2H5660
Extension Set w/0.22 micron high pressure extended life filter** & male Luer lock adapter. Filter has
passed bacterial & pyrogen retention testing for 96 hours. Replace set per CDC guidelines.
9 3.9 48
24801 *2H6480
Solution Set with DUO-VENT Spike, 0.22 micron high pressure extended life filter, 1 INTERLINK injection
site 6" from male Luer lock adapter. Non-DEHP.
102 10 48
19032 *2C7551
Nitroglycerin Set with PVC Pump Segment, DUO-VENT Spike and an INTERLINK Injection Site, Male
Luer Lock Adapter. Compatible with the FLO-GARD 6201 and FLO-GARD 6301 Series Volumetric Infusion
Pumps. Contains DEHP. Fluid path is sterile
103 60 48
30040 *2C1103
1.2 Micron Downstream Air Eliminating Filter, INTERLINK Y-Site, Approximate Volume 5.1 mL, Fluid path
is sterile, nonpyrogenic.
21
50
38410 2N3345
MICRO-VOLUME Extension Set, Male Luer Lock Adapter. Approximate Volume 0.32 mL. Sterile, non
pyrogenic.
36
50
31576 *2N3339
T-Connector Extension Set with a Retractable T-Connector, an INTERLINK Injection Site, Female Luer
Lock Adapter, non-DEHP, Approximate Volume 0.60 mL. Sterile package..
6.7
200
18701 *2C7451
Secondary Medication Set with male Luer lock adapter. INTERLINK lever lock Cannula (detached). Hanger
for primary solution container is provided.
37 10 48
30998 2C7461
Secondary Medication Set with male Luer lock adapter. Hanger for primary solution container is provided.
37 10 48
28978 2H8490
Secondary Medication Set with male Luer lock adapter. CLEARLINK Luer Activated Valve. Hanger for
primary solution container is provided. Non-DEHP.
37 10 48
28991 2H7462
Non-DEHP Secondary Medication Set with DUO-VENT Spike, Hanger, Male Luer Lock Adapter. For use
with FLO-GARD 6201and FLO-GARD 6301 series pumps. Fluid path is sterile.
37 10 48
23579 *2C6419
Solution Set with DUO-VENT spike and an INTERLINK Injection Site, Male Luer Lock Adapter,
Approximately 10 drops per mL, Approximate Length 92" (2.3 m). Compatible with the FLO-GARD 6201
and FLO-GARD 6301 Series Volumetric Infusion Pumps. Contains DEHP. Fluid path is sterile.
92 10 48
37075 2C6541
CONTINU-FLO Solution Set with DUO-VENT spike and 3 INTERLINK injection sites 6", 30" and 86" from
male Luer lock adapter. Set has tubing that is compatible with the COLLEAGUE Series Volumetric Infusion
Pumps and FLO-GARD 6201 and 6301 Series Volumetric Infusion Pumps
106 10 48
24957 *1W5000
Solution Set with vent cap, INTERLINK Injection Site,15 Micron Filter, Male Luer Lock Adapter. Compatible
with FLO-GARD 6201 & FLO-GARD 6301 Infusion Pumps. Contains DEHP. Sterile fluid path.
100 15 75
18698 *2C6425
Solution Set with 2 INTERLINK injection sites 6" and 30" from male Luer lock adapter. S*. Set has tubing
that is compatible with the COLLEAGUE Series Volumetric Infusion Pumps and FLO-GARD 6201 and
6301 Series Volumetric Infusion Pumps.
100 10 48
Injection Sites Products
ADMINISTRATION SETS
Baxter
BURETROL Solution Sets
DEHP Extension Sets
IV Catheter Extension Set
* SAFETY PRODUCTS indicated in green
*Indicates Special Order Item ** Indicates Dropship Item
IV Filtration Sets
Nitroglycerin Set with PVC Pump Segment
Non-DEHP Extension Sets
Secondary Medication Sets
Secondary Medication Sets - Non-DEHP
Solution Sets
1...,56,57,58,59,60,61,62,63,64,65 67,68,69,70,71,72,73,74,75,76,...120